Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2021, 07:54 AM
  • 05 1855_05 1854_08062021_011227.mp4

Date
08/06/2021
W/O
906772
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00490
PipeID
P07080
Time
12:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9098
Sewer Name
05 NARBONNE AVENUE TRUNK, SECTION 1(EAST)
City
LOMITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
WO_906772_TV05076_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
15 in.
Upstream MH
05 1855
Downstream MH
05 1854
Dir. of Survey
Downstream
Length Surveyed
349.3 ft.
Total Length
349.3 ft.
Structural Index
2
Structural Quick
2M00
Structural Rating
138
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
2
Overall Quick
Overall Rating
276
Pipe schematic from manhole 05 1855 to 05 1854
MH: 05 1855MH: 05 1854downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 18550 ft. MWL - Water Level, 15 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start78.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - 25% GREASE-LATERAL/OPEN114.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN162.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"213.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN265.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN312.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 3" - OPEN336.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN347 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish347 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish349.3 ft. AMH - Downstream Manhole, Survey Ends - 05 1854

Observations (15)

DistanceCodeObservation
162.2TFC
349.3AMH05 1854
312.9TFOPEN
2SSS
347DAGS
265.2TFOPEN
0MWM
0AMH05 1855
0MWL
114.1TFOPEN
213.9TFOPEN
78.1TF25% GREASE-LATERAL/OPEN
2DAGS
347SSS
336.3TFOPEN

Properties (7)

additional_info
630074080521201
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-08-06T00:54:14-07:00
documentation
PROPIPE
is_lateral_inspection
false