Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2021, 05:36 AM
  • 05 1778A_05 1778_08092021_223909.mp4

Date
08/09/2021
W/O
906737
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00473
PipeID
P07009
Time
10:36 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9306
Sewer Name
05 LOMITA TRUNK EXTENSION
City
TORRANCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
RFIR_WO_906737_TV05200_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1778
Downstream MH
05 1778A
Dir. of Survey
Upstream
Length Surveyed
9.7 ft.
Total Length
9.7 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 1778 to 05 1778A
MH: 05 1778MH: 05 1778Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 1778A0.7 ft. MGO - General Observation - ROACHES @ MH2.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish7.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES7.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start9.7 ft. MWM - Water Mark, 25 %of cross sectional area9.7 ft. MWL - Water Level, 20 %of cross sectional area9.7 ft. AMH - Upstream Manhole, Survey Begins - 05 1778

Observations (8)

DistanceCodeObservation
2DAGS
0MWM
9.7AMH05 1778A
2SSS
0MWL
9MGOROACHES @ MH
7SSS
0AMH05 1778

Properties (7)

additional_info
630074080921201
custom_field_three
RFIR NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2021-08-09T22:36:21-07:00
documentation
PROPIPE
is_lateral_inspection
false