- Date
- 08/10/2021
- W/O
- 906737
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00473
- PipeID
- P06998
- Time
- 12:32 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9306
- Sewer Name
- 05 LOMITA TRUNK EXTENSION
- City
- TORRANCE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- RFIR_WO_906737_TV05200_AUG2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 05 1771
- Downstream MH
- 05 1770
- Dir. of Survey
- Downstream
- Length Surveyed
- 419.4 ft.
- Total Length
- 419.4 ft.
- Structural Index
- 3
- Structural Quick
- 4O3P
- Structural Rating
- 743
- O&M Index
- 2
- O&M Quick
- 2P00
- O&M Rating
- 166
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 909
Pipe schematic from manhole 05 1771 to 05 1770 Observation photos (1)

8.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, 6ft, Start