- Date
- 08/05/2021
- W/O
- 906537
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00350
- PipeID
- P04564
- Time
- 11:28 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9223
- Sewer Name
- 02 GARFIELD AVENUE TRUNK
- City
- MONTEBELLO
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_906537_TV02062_AUG2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 24 in.
- Upstream MH
- 02 1170
- Downstream MH
- 02 1169
- Dir. of Survey
- Downstream
- Length Surveyed
- 328.4 ft.
- Total Length
- 328.4 ft.
- Structural Index
- 4
- Structural Quick
- 4K21
- Structural Rating
- 246
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 130
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 376
Pipe schematic from manhole 02 1170 to 02 1169 Observation photos (6)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

4.7 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

8.5 ft. - Crack Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

26.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

328.4 ft. - General Observation - COCKROACHES IN MANHOLE