- Date
- 08/03/2021
- W/O
- 906362
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00039
- PipeID
- P10187
- Time
- 4:00 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9215
- Sewer Name
- F JOINT OUTFALL F - UNIT 4
- City
- CERRITOS
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 39
- Purpose
- Routine Assessment
- Project
- WO_906362_TV02265_AUG2021
- Sewer Type
- Siphon
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Width
- 12 in.
- Upstream MH
- F 0234
- Downstream MH
- F 0256
- Dir. of Survey
- Upstream
- Length Surveyed
- 2 ft.
- Total Length
- 2 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole F 0234 to F 0256 Observation photos (3)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES

2 ft. - Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: YES

2 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.