Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2021, 05:11 AM
  • 02 1179_02 1178_08052021_222254.mp4

Date
08/05/2021
W/O
906777
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00262
PipeID
P04604
Time
10:11 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9222
Sewer Name
02 GARFIELD AVENUE DIVERSION TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_906777_TV02399_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
21 in.
Upstream MH
02 1179
Downstream MH
02 1178
Dir. of Survey
Downstream
Length Surveyed
310.5 ft.
Total Length
310.5 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2K00
O&M Rating
122
Overall Index
2
Overall Quick
Overall Rating
128
Pipe schematic from manhole 02 1179 to 02 1178
MH: 02 1179MH: 02 1178downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 11790 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start4.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES149.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES308.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish310.5 ft. MGO - General Observation - COCKROACHES IN MANHOLE310.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1178310.5 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    4.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    149.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    310.5 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (11)

DistanceCodeObservation
310.5MGOCOCKROACHES IN MANHOLE
0MWM
4.8CM
0AMH02 1179
310.5AMH02 1178
0MWL
0MGOCOCKROACHES IN MANHOLE
310.5MGOACTIVE CONNECTION AT MH 3 O'CLOCK
149.6CM
2DAGS
308.6DAGS

Properties (7)

additional_info
630069080521201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-08-05T22:11:55-07:00
documentation
PRO PIPE
is_lateral_inspection
false