Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 13, 2021, 10:42 AM
  • 08 0636_08 0460_08132021_035348.mp4

Date
08/13/2021
W/O
906766
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00026
PipeID
P00518
Time
3:42 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9317
Sewer Name
08 216TH STREET TRUNK
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_906766_TV08103_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
30 in.
Upstream MH
08 0636
Downstream MH
08 0460
Dir. of Survey
Downstream
Length Surveyed
268.2 ft.
Total Length
268.2 ft.
Structural Index
3
Structural Quick
443B
Structural Rating
55
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
55
Pipe schematic from manhole 08 0636 to 08 0460
MH: 08 0636MH: 08 0460downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 06360 ft. MWL - Water Level, 5 %of cross sectional area2.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start65.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish249.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES255.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start268.2 ft. AMH - Downstream Manhole, Survey Ends - 08 0460268.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK268.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    249.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    255.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
268.2AMH08 0460
249.9FM
0MWM
0AMH08 0636
268.2MGOCONNECTION AT THE MH 3 OC'LOCK
255.1FM
268.2FM
0MWL
2.1CM
65.2CM

Properties (8)

additional_info
630074081221204
custom_field_three
CRACKS/ FRACTURE'S
custom_field_two
3
customer
1
datetime
2021-08-13T03:42:38-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
32524