Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2021, 11:05 AM
  • C 0683_C 0682_08092021_041300.mp4

Date
08/09/2021
W/O
906261
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00126
PipeID
P24966
Time
4:05 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9303
Sewer Name
C JOINT OUTFALL C - UNIT 4A
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
24
Purpose
Routine Assessment
Project
RFIR_WO_906261_TV03150_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
C 0683
Downstream MH
C 0682
Dir. of Survey
Downstream
Length Surveyed
85.2 ft.
Total Length
85.2 ft.
Structural Index
4
Structural Quick
4A35
Structural Rating
63
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
63
Pipe schematic from manhole C 0683 to C 0682
MH: C 0683MH: C 0682downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - C 06834.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES28.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish28.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start85.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish85.2 ft. AMH - Downstream Manhole, Survey Ends - C 068285.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    28.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
28.1CM
0MWL
85.2FM
4.2CM
0MWM
0MGOCONNECTION AT THE MH 3 OC'LOCK
28.4FM
9FM
85.2AMHC 0682
85.2MGOCONNECTION AT THE MH 3 OC'LOCK
0AMHC 0683

Properties (7)

additional_info
630074080921005
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-08-09T04:05:46-07:00
documentation
PROPIPE
is_lateral_inspection
false