- Date
- 08/16/2021
- W/O
- 906198
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00545
- PipeID
- P07175
- Time
- 1:07 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9318
- Sewer Name
- 05 9TH STREET CONNECTION TRUNK
- City
- SAN PEDRO
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 47A
- Purpose
- Routine Assessment
- Project
- RFIR_WO_906198_TV05318_AUG2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Width
- 21 in.
- Upstream MH
- 05 1975
- Downstream MH
- J 0182
- Dir. of Survey
- Downstream
- Length Surveyed
- 39.5 ft.
- Total Length
- 39.5 ft.
- Structural Index
- 3
- Structural Quick
- 3621
- Structural Rating
- 20
- O&M Index
- 3
- O&M Quick
- 4122
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 28
Pipe schematic from manhole 05 1975 to J 0182 Observation photos (5)

8.6 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

10.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

31.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

33.5 ft. - Deposits Settled Other, 25 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start

39.5 ft. - Downstream Manhole, Survey Ends - J 0182 ZOOMED IN