F 0024_F 0023_8272021_041856.mp4
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
91.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
98.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR BROKEN
107.2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - LONG REBAR
418.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR BROKEN MISSING
430.8 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN MISSING
| Distance | Code | Observation |
|---|---|---|
| 0 | AMH | 4:25AM |
| 473.4 | SRC | LONG REBAR CORRODED |
| 91.2 | SRC | CIRCUM REBAR |
| 2 | SSS | BLISTERING CONCRETE |
| 430.8 | SRC | CIRCUM REBAR BROKEN MISSING |
| 473.4 | SAM | SEVERE AGG |
| 473.4 | SSS | BLISTERING CONCRETE |
| 473.8 | AMH | 4:55AM |
| 473.4 | SRC | CIRCUM REBAR CORRODED |
| 0 | MWL | — |
| 107.2 | SRC | LONG REBAR |
| 418.4 | SRC | CIRCUM REBAR BROKEN MISSING |
| 0 | MWM | — |
| 2 | SAM | SEVERE AGG |
| 2 | SRC | CIRCUM REBAR |
| 473.4 | SRC | CIRCUM REBAR BROKEN MISSING |
| 98.6 | SRC | CIRCUM REBAR BROKEN |