Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 25, 2021, 09:13 AM
  • F 0029_F 0028_8252021_021601.mp4

Date
08/25/2021
W/O
0901411
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00033
PipeID
P10119
Time
2:13 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1922
Sewer Name
F JOINT OUTFALL F - UNIT 1
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
20210824MDM_JOINT_OUTFALL_F_UNIT_1
Material
Reinforced Concrete Pipe
Shape
Circular
Height
69 in.
Upstream MH
F 0029
Downstream MH
F 0028
Dir. of Survey
Downstream
Length Surveyed
495.7 ft.
Total Length
495.7 ft.
Structural Index
5
Structural Quick
5741
Structural Rating
39
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
43
Pipe schematic from manhole F 0029 to F 0028
MH: F 0029MH: F 0028downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:15AM0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR9.9 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN33.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR BROKEN61.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN HANGING77.7 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN134.5 ft. SRC - Surface Reinforcement Corroded, from 09 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN SPORATIC479.8 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR495.1 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG495.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO, Finish - CIRCUM REBAR BROKEN SPORATIC495.1 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR495.7 ft. AMH - Downstream Manhole, Survey Ends - 2:45AM

Observation photos (8)

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN

    9.9 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR BROKEN

    33.1 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR BROKEN

  • Surface Reinforcement Corroded, from 09 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN HANGING

    61.2 ft. - Surface Reinforcement Corroded, from 09 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN HANGING

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN

    77.7 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN

  • Surface Reinforcement Corroded, from 09 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN SPORATIC

    134.5 ft. - Surface Reinforcement Corroded, from 09 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN SPORATIC

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    479.8 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

Observations (15)

DistanceCodeObservation
2SAMSEVERE AGG
495.7AMH2:45AM
0MWL
0AMH2:15AM
9.9SRCCIRCUM REBAR BROKEN
61.2SRCCIRCUM REBAR BROKEN HANGING
479.8SRCLONG CIRCUM REBAR
2SRCLONG CIRCUM REBAR
0MWM
495.1SAMSEVERE AGG
495.1SRCCIRCUM REBAR BROKEN SPORATIC
77.7SRCCIRCUM REBAR BROKEN
495.1SRCLONG CIRCUM REBAR
33.1SRCCIRCUM REBAR BROKEN
134.5SRCCIRCUM REBAR BROKEN SPORATIC

Properties (6)

custom_field_three
LONG CIRCUM REBAR CORRODED & BROKEN
custom_field_two
1
customer
LACSD
datetime
2021-08-25T02:13:36-07:00
documentation
MARTIN,REVELES,OLIVER 111,BARR,
is_lateral_inspection
false