Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 27, 2021, 08:23 AM
  • C JOINT_C 0499_8272021_020358.mp4

Date
08/27/2021
W/O
0880009
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00120
PipeID
P20574
Time
1:23 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1926
Sewer Name
C JOINT OUTFALL C - UNIT 3A
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
18
Purpose
Capital Improvement Program Assesment
Project
20210827MDM_JOINT_OUTFALL_C_UNIT_3A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
72 in.
Upstream MH
C JOINT
Downstream MH
C 0499
Dir. of Survey
Downstream
Length Surveyed
8.7 ft.
Total Length
8.7 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole C JOINT to C 0499
MH: C JOINTMH: C 0499downstream0 ft. MWL - Water Level, 80 %of cross sectional area0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:302 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE2 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG8 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - SEVERE AGG8 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - PEELING CONCRETE8.7 ft. AMH - Downstream Manhole, Survey Ends - 3:10AM

Observation photos (3)

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE

    2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG

    2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Downstream Manhole, Survey Ends - 3:10AM

    8.7 ft. - Downstream Manhole, Survey Ends - 3:10AM

Observations (8)

DistanceCodeObservation
8.7AMH3:10AM
8SAVSEVERE AGG
0MWL
2SSSPEELING CONCRETE
0MWM
0AMH2:30
8SSSPEELING CONCRETE
2SAVSEVERE AGG

Properties (6)

custom_field_three
SEVERE AGG VISIBLE
custom_field_two
3
customer
LACSD
datetime
2021-08-27T01:23:16-07:00
documentation
MARTIN,REVELES,OLIVER 111,RAMIREZ
is_lateral_inspection
false