- Date
- 10/16/2017
- W/O
- 0630073
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00408
- PipeID
- P11747
- Time
- 4:46 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0652
- Sewer Name
- 04 DISTRICT #4 OUTFALL TRUNK
- City
- BEVERLY HILLS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 04
- Page No.
- 03
- Purpose
- Routine Assessment
- Project
- 20171016MDM_DISTRICT_4_OUTFALL_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 04 0019
- Downstream MH
- 04 0018
- Dir. of Survey
- Downstream
- Length Surveyed
- 62.8 ft.
- Total Length
- 62.8 ft.
- Structural Index
- 2
- Structural Quick
- 2300
- Structural Rating
- 6
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole 04 0019 to 04 0018 Observation photos (5)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING LAITANCE COAT

8 ft. - General Observation - 21" RCP

18.9 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT

23.8 ft. - General Photograph - 21" RCP

58 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING LAITANCE COAT