Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 24, 2017, 08:48 AM
  • 16 0670_16 0669_10242017_023714.mp4

  • 16 0670_16 0669_10242017_025733.mp4

Date
10/24/2017
W/O
0667680
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z01074
PipeID
P13682
Time
1:48 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0658
Sewer Name
16 ALLEN AVENUE RELIEF TRUNK, SECTION 3
City
SAN GABRIEL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
10242017VMR_ALLEN_AVENUE_RELIEF_TRUNKSECTION_3
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
16 0669
Downstream MH
16 0670
Dir. of Survey
Upstream
Length Surveyed
419.5 ft.
Total Length
419.5 ft.
Structural Index
2
Structural Quick
2211
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
5
Pipe schematic from manhole 16 0669 to 16 0670
MH: 16 0669MH: 16 0670upstream0 ft. AMH - Upstream Manhole, Survey Ends - 5:10 AM0.3 ft. MGO - General Observation - Carbon cannister371.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES387.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES396 ft. CC - Crack Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES407.1 ft. MGO - General Observation - Reset419.5 ft. AMH - Downstream Manhole, Survey Begins - 02:40 AM419.5 ft. MWL - Water Level, 30 %of cross sectional area419.5 ft. MWM - Water Mark, 40 %of cross sectional area

Observations (9)

DistanceCodeObservation
23.5CC
0AMH02:40 AM
419.2MGOCarbon cannister
12.4MGOReset
31.8CL
0MWL
48.3CL
419.5AMH5:10 AM
0MWM

Properties (6)

custom_field_two
3
customer
LACSD
datetime
2017-10-24T01:48:36-07:00
documentation
REVELES,MANANES,OLIVER III
is_lateral_inspection
false
year_laid
19831122