Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 23, 2017, 11:26 AM
  • Section#2_04 0087_04 0086__10232017__G6855.mp4

Date
10/23/2017
W/O
0667677
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00417
PipeID
P11825
Time
4:26 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6855
Sewer Name
04 WARING AVENUE TRUNK
City
West Hollywood
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
10232017VMR_WARING_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
04 0087
Downstream MH
04 0086
Dir. of Survey
Downstream
Length Surveyed
287 ft.
Total Length
287 ft.
Structural Index
2
Structural Quick
332A
Structural Rating
38
O&M Index
1
O&M Quick
1300
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
41
Pipe schematic from manhole 04 0087 to 04 0086
MH: 04 0087MH: 04 0086downstream0 ft. AMH - Upstream Manhole, Survey Begins - 04:26 AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2.2 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES5.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN5.8 ft. CM - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES7.4 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES7.6 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4"9 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES9.3 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: NO9.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"10.8 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES10.8 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES13.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES18.5 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES21.9 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES24.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN26.2 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES37.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"40.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 4" - OPEN44.9 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES45.9 ft. RFJ - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YESR - 5%46.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES50.2 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES53.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"55.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN59.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES64.7 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES69.6 ft. RFJ - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YESR69.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES70.6 ft. RFJ - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR71.5 ft. CC - Crack Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES71.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"74.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN75.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ACTIVE76.6 ft. CC - Crack Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES84.3 ft. CC - Crack Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES287 ft. AMH - Downstream Manhole, Survey Ends - 5:34 AM

Observation photos (1)

  • Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YESR - 5%

    45.9 ft. - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YESR - 5%

Observations (38)

DistanceCodeObservation
2.2CM
5.1TFOPEN
71.8TFA
287AMH5:34 AM
9CC
37.6TFA
7.6TF
40.9TFOPEN
55.5TFOPEN
64.7CL
24.7TFOPEN
10.8CL
50.2CL
13.3CL
59.5CL
5.8CM
0AMH04:26 AM
9.3CM
74.3TFOPEN
7.4CL
70.6RFJ
0MWM
18.5CL
69.7CL
10.8CL
53.8TF
84.3CC
71.5CC
46.7CL
44.9CL
76.6CC
21.9CC
69.6RFJ
9.3TF
0MWL
45.9RFJ5%
26.2CL
75.2TFCACTIVE

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2017-10-23T04:26:00-07:00
documentation
REVELES,MANANES,OLIVER III
is_lateral_inspection
false