Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 29, 2017, 06:07 AM
  • 16 0058_16 0057 _28092017_230732.mp4

Date
09/28/2017
W/O
658234
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00639
PipeID
P13071
Time
11:07 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4987
Sewer Name
16 ALLEN AVENUE TRUNK, SECTS 1,2,&4
City
SAN MARINO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
01
Purpose
Routine Assessment
Project
WO_658234_TV16004_SEP2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
16 0058
Downstream MH
16 0057
Dir. of Survey
Downstream
Length Surveyed
177.1 ft.
Total Length
177.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 16 0058 to 16 0057
MH: 16 0058MH: 16 0057downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 00582.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start176 ft. MGO - General Observation - SPALLING THROUGHOUT THE REACH177.1 ft. AMH - Downstream Manhole, Survey Ends - 16 0057177.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
177.1AMH16 0057
177.1DAGS
2.9DAGS
0MWM
0MWL
0AMH16 0058
176MGOSPALLING THROUGHOUT THE REACH

Properties (6)

additional_info
SC345979
custom_field_two
3
customer
LACSD
datetime
2017-09-28T23:07:08-07:00
documentation
PROPIPE
is_lateral_inspection
false