Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2017, 07:54 AM
  • 14 1127_14 1126_09282017_005509.mp4

Date
09/28/2017
W/O
658225
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01179
PipeID
P26079
Time
12:54 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4736
Sewer Name
14 WEST SIDE RELIEF TRUNK
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
10
Purpose
Routine Assessment
Project
WO_658225_TV14056_SEP2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
14 1127
Downstream MH
14 1126
Dir. of Survey
Downstream
Length Surveyed
108.4 ft.
Total Length
108.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2C00
O&M Rating
42
Overall Index
2
Overall Quick
Overall Rating
42
Pipe schematic from manhole 14 1127 to 14 1126
MH: 14 1127MH: 14 1126downstream0 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 04 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 14 11270 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start14.5 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start85 ft. MGO - General Observation - GASKET HANGING OUT @ 01 O'CLOCK108.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish108.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish108.4 ft. AMH - Downstream Manhole, Survey Ends - 14 1126

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    14.5 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
108.1DAGS
0MGOACTIVE CONN. INSIDE THE MH. @ 04 O'CLOCK
14.5DAE
108.4AMH14 1126
0AMH14 1127
0MWM
85MGOGASKET HANGING OUT @ 01 O'CLOCK
108.1DAE
0MWL
2DAGS

Properties (7)

additional_info
SC345749
custom_field_two
4
customer
LACSD
datetime
2017-09-28T00:54:46-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
40175