2 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR UNDER MAG COAT
2 ft. - General Observation - MAG COAT 100%START 10:00 TO 2:00
2 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
99.2 ft. - Surface Aggregate Projecting, from 01 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
132.5 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT
183.2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR UNDER MAG COAT
183.2 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN
358.7 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - BROKEN CIRCUM REBAR
545.6 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - BROKEN MISSING REBAR
550.7 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - BROKEN REBAR
565.2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - BROKEN REBAR
610.1 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR IN FLOW
614.6 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
751.2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - BROKEN
882.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR IN FLOW
882.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BNROKEN MISSING REBAR
882.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
887 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR IN FLOW DOWNSTREAM
887 ft. - Surface Aggregate Missing, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG UNDER MAG COAT
887 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 10" - ACTIVE VIEW DOWNSTREAM
889.1 ft. - Survey Abandoned - REBAR HANGING IN FLOW 4:30AM
| Distance | Code | Observation |
|---|---|---|
| 550.7 | TF | ACTIVE |
| 887 | SRC | BROKEN REBAR IN FLOW DOWNSTREAM |
| 889.1 | MSA | REBAR HANGING IN FLOW 4:30AM |
| 887 | SAM | SEVERE AGG UNDER MAG COAT |
| 2 | SRV | CIRCUM REBAR UNDER MAG COAT |
| 0 | AMH | 2:30AM |
| 183.2 | SRC | CIRCUM REBAR UNDER MAG COAT |
| 132.5 | SRV | CIRCUM REBAR UNDER MAG COAT |
| 887 | SRC | BROKEN MISSING REBAR |
| 550.7 | SRC | BROKEN REBAR |
| 0 | MWL | — |
| 14.2 | TF | ACTIVE |
| 565.2 | SRC | BROKEN REBAR |
| 882.2 | SRC | BROKEN MISSING REBAR IN FLOW |
| 887 | SRV | CIRCUM REBAR UNDER MAG COAT |
| 882.2 | SRC | BNROKEN MISSING REBAR |
| 610.1 | SRC | BROKEN MISSING REBAR IN FLOW |
| 0 | MWM | — |
| 545.6 | SRC | BROKEN MISSING REBAR |
| 60.1 | TF | OPEN |
| 614.6 | SRC | BROKEN MISSING REBAR |
| 183.2 | TF | OPEN |
| 2 | SAM | SEVERE AGG UNDER MAG COAT |
| 882.2 | SRC | BROKEN MISSING REBAR |
| 358.7 | SRC | BROKEN CIRCUM REBAR |
| 751.2 | SRC | BROKEN |
| 2 | MGO | MAG COAT 100%START 10:00 TO 2:00 |
| 2 | SAP | SEVERE AGG |
| 887 | TF | ACTIVE VIEW DOWNSTREAM |
| 99.2 | SAP | SEVERE AGG |
| 887 | SAP | SEVERE AGG |