Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2018, 07:41 AM
  • 05 1987_J 0159 _26072018_005249.mp4

Date
07/26/2018
W/O
717908
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00538
PipeID
P07179
Time
12:41 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5795
Sewer Name
05 WESTERN AVENUE TRUNK
City
RANCHO PALOS VERDES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
44
Purpose
Routine Assessment
Project
WO_717908_TV05116_AUG2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1987
Downstream MH
J 0159
Dir. of Survey
Downstream
Length Surveyed
80.4 ft.
Total Length
80.4 ft.
Structural Index
3
Structural Quick
4232
Structural Rating
16
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 05 1987 to J 0159
MH: 05 1987MH: J 0159downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 19876.1 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES40.5 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES45 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES64.5 ft. CM - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES75.3 ft. FM - Fracture Multiple, from 11 to 05 o'clock, within 8 inches of joint: YES80.4 ft. AMH - Downstream Manhole, Survey Ends - J 0159

Observation photos (5)

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    6.1 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES

    40.5 ft. - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    45 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

    64.5 ft. - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 05 o'clock, within 8 inches of joint: YES

    75.3 ft. - Fracture Multiple, from 11 to 05 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
0MWM
0MWL
80.4AMHJ 0159
75.3FM
40.5FC
45FM
0AMH05 1987
6.1CM
64.5CM

Properties (6)

additional_info
SC364707
custom_field_two
3
customer
LACSD
datetime
2018-07-26T00:41:43-07:00
documentation
PROPIPE
is_lateral_inspection
false