Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 27, 2018, 10:33 AM
  • 08 0335_08 0334 _27072018_034403.mp4

Date
07/27/2018
W/O
717824
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00003
PipeID
P00385
Time
3:33 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5800
Sewer Name
08 DAVIDSON CITY TRUNK, SECTS 1,2,&3
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
14
Purpose
Routine Assessment
Project
WO_717824_TV08104_AUG2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
08 0335
Downstream MH
08 0334
Dir. of Survey
Downstream
Length Surveyed
349.7 ft.
Total Length
349.7 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
207
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
207
Pipe schematic from manhole 08 0335 to 08 0334
MH: 08 0335MH: 08 0334downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 03350 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"103 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"174.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"317.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"349.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish349.7 ft. AMH - Downstream Manhole, Survey Ends - 08 0334349.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0AMH08 0335
174.7TFA
349.7SAP
317.1TF
103TF
3.4TF
0MWL
349.7AMH08 0334
2.2SAP
0MWM
349.7MGOCONNECTION AT MH 3 O'CLOCK

Properties (6)

additional_info
SC364712
custom_field_two
3
customer
LACSD
datetime
2018-07-27T03:33:45-07:00
documentation
PROPIPE
is_lateral_inspection
false