Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 27, 2018, 08:01 AM
  • 08 0638_08 0341 _27072018_011640.mp4

Date
07/27/2018
W/O
717824
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00003
PipeID
P00392
Time
1:01 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5800
Sewer Name
08 DAVIDSON CITY TRUNK, SECTS 1,2,&3
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
15
Purpose
Routine Assessment
Project
WO_717824_TV08104_AUG2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
08 0638
Downstream MH
08 0341
Dir. of Survey
Downstream
Length Surveyed
332.8 ft.
Total Length
332.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3B00
O&M Rating
39
Overall Index
3
Overall Quick
Overall Rating
42
Pipe schematic from manhole 08 0638 to 08 0341
MH: 08 0638MH: 08 0341downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 06380 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area6.3 ft. MGO - General Observation - MAG COAT31.6 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start96.4 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish313.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"315.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES321.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"332.8 ft. AMH - Downstream Manhole, Survey Ends - 08 0341332.8 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (2)

  • Deposits Settled Other,  15 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    31.6 ft. - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    315.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
0AMH08 0638
0MWL
96.4DSZ
321.4TF
332.8AMH08 0341
0MWM
315.2SAP
332.8MGOCONNECTION AT MH 9 O'CLOCK
313.8TFA
31.6DSZ
6.3MGOMAG COAT

Properties (6)

additional_info
SC364712
custom_field_two
4
customer
LACSD
datetime
2018-07-27T01:01:03-07:00
documentation
PROPIPE
is_lateral_inspection
false