22 0328_22 0327_08112021_235104.mp4
2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - General Observation - MAG COAT
2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 8"
136.4 ft. - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"
145.3 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"
209.1 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"
273.3 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"
313.6 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"
386 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"
506.5 ft. - Surface Reinforcement Visible, from 01 to 04 o'clock, within 8 inches of joint: YES, Start
506.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"
| Distance | Code | Observation |
|---|---|---|
| 2 | SRV | — |
| 145.3 | TB | — |
| 2 | SAV | — |
| 506.5 | SRV | — |
| 2 | MGO | MAG COAT |
| 136.4 | TBC | — |
| 386 | TB | — |
| 209.1 | TB | — |
| 23.1 | SRV | — |
| 574.4 | AMH | 22 0327 |
| 273.3 | TB | — |
| 9 | TB | — |
| 525.9 | SRV | — |
| 313.6 | TB | — |
| 0 | AMH | 22 0328 |
| 506.5 | TB | — |
| 2.1 | SSS | — |
| 0 | MWM | — |
| 571.2 | SSS | — |
| 0 | MWL | — |
| 571.2 | SAV | — |