22 0326_22 0325_08122021_011347.mp4
2 ft. - General Observation - MAG COAT
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
196.3 ft. - Surface Reinforcement Visible, from 01 to 04 o'clock, within 8 inches of joint: NO
201.6 ft. - Surface Reinforcement Visible, from 08 to 10 o'clock, within 8 inches of joint: YES
261.9 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"
362.7 ft. - Surface Reinforcement Visible, at 04 o'clock, within 8 inches of joint: NO
403.4 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"
532 ft. - Tap Break-In Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"
612.9 ft. - Tap Break-In Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 624.6 | SAV | — |
| 627.3 | AMH | 22 0325 |
| 0 | AMH | 22 0326 |
| 201.6 | SRV | — |
| 362.7 | SRV | — |
| 2 | MGO | MAG COAT |
| 2 | SSS | — |
| 612.9 | TBC | — |
| 0 | MGO | CONNECTION AT MH 3 O'CLOCK |
| 2 | SAV | — |
| 196.3 | SRV | — |
| 532 | TBC | — |
| 624.6 | SSS | — |
| 0 | MWL | — |
| 261.9 | TB | — |
| 403.4 | TB | — |