- Date
- 08/12/2021
- W/O
- 906728
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00891
- PipeID
- P19915
- Time
- 2:16 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9232
- Sewer Name
- 32 VALENCIA TRUNK
- City
- SANTA CLARITA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 32
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- RFIR_WO_906728_TV32044_AUG2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 32 0229
- Downstream MH
- 32 0163
- Dir. of Survey
- Downstream
- Length Surveyed
- 30.1 ft.
- Total Length
- 30.1 ft.
- Structural Index
- 4
- Structural Quick
- 5434
- Structural Rating
- 36
- O&M Index
- 3
- O&M Quick
- 4122
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 44
Pipe schematic from manhole 32 0229 to 32 0163 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

5.5 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

5.5 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

30.1 ft. - General Observation - COCKROACHES IN MANHOLE