Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 12, 2018, 08:24 AM
  • 02 1833_02 1832_9122018_012859.mp4

Date
09/12/2018
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00240
PipeID
P04183
Time
1:24 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0973
Sewer Name
02 CITY TERRACE DIVERSION EXTENSION TRUNK
City
LOS ANGLES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Capital Improvement Program Assesment
Project
20180912MDM_CITY_TERRACE_DIVERSION_EXTENSION_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
02 1833
Downstream MH
02 1832
Dir. of Survey
Downstream
Length Surveyed
245.2 ft.
Total Length
245.2 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1833 to 02 1832
MH: 02 1833MH: 02 1832downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:25AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. MGO - General Observation - MAG COAT 100% START 8:00 TO 4:002 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE245.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - FLAKING CONCRETE245.2 ft. MGO - General Observation - MAG COAT 100% FINISH245.2 ft. MSA - Survey Abandoned - CABLE PROBLEM-WILL COMPLETE REVERSE

Observation photos (3)

  • General Observation - MAG COAT 100% START 8:00 TO 4:00

    2 ft. - General Observation - MAG COAT 100% START 8:00 TO 4:00

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

  • Survey Abandoned - CABLE PROBLEM-WILL COMPLETE REVERSE

    245.2 ft. - Survey Abandoned - CABLE PROBLEM-WILL COMPLETE REVERSE

Observations (8)

DistanceCodeObservation
0AMH1:25AM
245.2SSSFLAKING CONCRETE
0MWL
2MGOMAG COAT 100% START 8:00 TO 4:00
0MWM
2SSSFLAKING CONCRETE
245.2MGOMAG COAT 100% FINISH
245.2MSACABLE PROBLEM-WILL COMPLETE REVERSE

Properties (6)

custom_field_three
100% MAG COAT
custom_field_two
5
customer
LACSD
datetime
2018-09-12T01:24:26-07:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false