Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 11, 2018, 08:08 AM
  • Section#5_G 0319_G 0318__9112018__I0065.mp4

Date
09/11/2018
W/O
0727987
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00228
PipeID
P01755
Time
1:08 AM
Certificate
U-1014-0602253
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0065
Sewer Name
G JOINT OUTFALL G- UNIT 9 TRUNK
City
SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Capital Improvement Program Assesment
Project
20180907MDM_JOINT_OUTFALL_G_UNIT_9_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
G 0319
Downstream MH
G 0318
Dir. of Survey
Downstream
Length Surveyed
464.7 ft.
Total Length
464.7 ft.
Structural Index
4
Structural Quick
5E4Q
Structural Rating
513
O&M Index
2
O&M Quick
322R
O&M Rating
192
Overall Index
3
Overall Quick
Overall Rating
705
Pipe schematic from manhole G 0319 to G 0318
MH: G 0319MH: G 0318downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:05AMAM2 ft. MGO - General Observation - 80% MISSING TILES START2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - MISSING TILES & SLUDGE2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES15.9 ft. MGO - General Observation - 10% MISSING TILES START43.4 ft. MGO - General Observation - 95% MISSING TILES 2 JOINT SECTIONS45.8 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR63.3 ft. MGO - General Observation - 100% MISSING TILES 1 JOINT SECTION66.1 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR75.9 ft. MGO - General Observation - 100% MISSING TILES 1 JOINT SECTION76.3 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR79.3 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - CIRCUM REBAR86.8 ft. MGO - General Observation - 80% MISSING TILES START93 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR97.2 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR112.8 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR132.6 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - MISSING TILES & SLUDGE144.7 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR144.7 ft. MGO - General Observation - MISSING TILES 10% START176.5 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR REBAR176.5 ft. MGO - General Observation - 90% MISSING TILES 2 PIPE JOINTS192.5 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG & CIRCUM REBAR195.7 ft. MGO - General Observation - 30% MISSING TILES START224.1 ft. MGO - General Observation - 90% MISSING TILES 1 PIPE JOINT225.8 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR236.4 ft. MGO - General Observation - 100% MISSING TILES 1 PIPE JOINT242.9 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - MISSING TILES & SLUDGE245.3 ft. MGO - General Observation - 100% MISSING TILES 1 PIPE JOINT245.3 ft. SRC - Surface Reinforcement Corroded, from 02 to 04 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR259.7 ft. MGO - General Observation - 40% MISSING TILES START285.8 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR308.7 ft. MGO - General Observation - 100% MISSING TILES 1 PIPE JOINT308.7 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR313 ft. MGO - General Observation - 10% MISSING TILES START328.4 ft. SRC - Surface Reinforcement Corroded, from 02 to 04 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR343.9 ft. MGO - General Observation - 195% MISSING TILES START346.6 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR383 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - MISSING TILES390.7 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR390.7 ft. MGO - General Observation - 40% MISSING TILES START426.7 ft. MGO - General Observation - 20% MISSING TILES445 ft. MGO - General Observation - 100% MISSING TILES 1PIPE JOINT464.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG AREAS OF MISSING TILES464.2 ft. MGO - General Observation - MH CONN 3:00 ACTIVE464.2 ft. MGO - General Observation - 20% MISSING TILES FINISH464.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - MISSING TILES SLUDGE464.7 ft. AMH - Downstream Manhole, Survey Ends - 3:05AM

Observation photos (25)

  • General Observation - 80% MISSING TILES START

    2 ft. - General Observation - 80% MISSING TILES START

  • Deposits Settled Other,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start - MISSING TILES & SLUDGE

    2 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - MISSING TILES & SLUDGE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

  • General Observation - 10% MISSING TILES START

    15.9 ft. - General Observation - 10% MISSING TILES START

  • General Observation - 95% MISSING TILES 2 JOINT SECTIONS

    43.4 ft. - General Observation - 95% MISSING TILES 2 JOINT SECTIONS

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    45.8 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    66.1 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • General Observation - 100% MISSING TILES 1 JOINT SECTION

    75.9 ft. - General Observation - 100% MISSING TILES 1 JOINT SECTION

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR

    76.3 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - CIRCUM REBAR

    79.3 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - CIRCUM REBAR

  • General Observation - 80% MISSING TILES START

    86.8 ft. - General Observation - 80% MISSING TILES START

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    93 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Deposits Settled Other,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: NO - MISSING TILES & SLUDGE

    132.6 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - MISSING TILES & SLUDGE

  • General Observation - MISSING TILES 10% START

    144.7 ft. - General Observation - MISSING TILES 10% START

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR REBAR

    176.5 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR REBAR

  • General Observation - 30% MISSING TILES START

    195.7 ft. - General Observation - 30% MISSING TILES START

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    225.8 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - MISSING TILES & SLUDGE

    242.9 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - MISSING TILES & SLUDGE

  • Surface Reinforcement Corroded, from 02 to 04 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    245.3 ft. - Surface Reinforcement Corroded, from 02 to 04 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    285.8 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    308.7 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 02 to 04 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    328.4 ft. - Surface Reinforcement Corroded, from 02 to 04 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • General Observation - 195% MISSING TILES START

    343.9 ft. - General Observation - 195% MISSING TILES START

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    346.6 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO - MISSING TILES

    383 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - MISSING TILES

Observations (49)

DistanceCodeObservation
245.3MGO100% MISSING TILES 1 PIPE JOINT
2MGO80% MISSING TILES START
97.2SRVCIRCUM REBAR
426.7MGO20% MISSING TILES
390.7SRVCIRCUM REBAR
195.7MGO30% MISSING TILES START
346.6SRVCIRCUM REBAR
112.8SRVCIRCUM REBAR
2DSZMISSING TILES & SLUDGE
464.2SAMSEVERE AGG AREAS OF MISSING TILES
45.8SRVCIRCUM REBAR
464.2MGOMH CONN 3:00 ACTIVE
93SRVCIRCUM REBAR
390.7MGO40% MISSING TILES START
63.3MGO100% MISSING TILES 1 JOINT SECTION
0MWL
0MWM
192.5SRVLONG & CIRCUM REBAR
86.8MGO80% MISSING TILES START
79.3SRVCIRCUM REBAR
445MGO100% MISSING TILES 1PIPE JOINT
66.1SRVCIRCUM REBAR
464.2MGO20% MISSING TILES FINISH
75.9MGO100% MISSING TILES 1 JOINT SECTION
224.1MGO90% MISSING TILES 1 PIPE JOINT
259.7MGO40% MISSING TILES START
15.9MGO10% MISSING TILES START
343.9MGO195% MISSING TILES START
245.3SRCLONG & CIRCUM REBAR
313MGO10% MISSING TILES START
464.7AMH3:05AM
2SAMSEVERE AGG AREAS OF MISSING TILES
0AMH2:05AMAM
43.4MGO95% MISSING TILES 2 JOINT SECTIONS
308.7MGO100% MISSING TILES 1 PIPE JOINT
76.3SRVCIRCUM REBAR
144.7SRVCIRCUM REBAR
328.4SRCLONG & CIRCUM REBAR
285.8SRVCIRCUM REBAR
236.4MGO100% MISSING TILES 1 PIPE JOINT
308.7SRVCIRCUM REBAR
383DSZMISSING TILES
225.8SRVCIRCUM REBAR
242.9DSZMISSING TILES & SLUDGE
176.5SRVLONG & CIRCUM REBAR REBAR
132.6DSZMISSING TILES & SLUDGE
144.7MGOMISSING TILES 10% START
176.5MGO90% MISSING TILES 2 PIPE JOINTS
464.2DSZMISSING TILES SLUDGE

Properties (6)

custom_field_three
LONG & CIRCUM REBAR CORRODED
custom_field_two
2
customer
LACSD
datetime
2018-09-11T01:08:42-07:00
documentation
MARTIN,REVELES,OLIVER 111,YOUNG
is_lateral_inspection
false