- Date
- 07/15/2021
- W/O
- 901521
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00941
- PipeID
- P11161
- Time
- 11:12 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9000
- Sewer Name
- H JOINT OUTFALL H - UNIT 9B
- City
- WEST COVINA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 30
- Purpose
- Routine Assessment
- Project
- RFIR_WO_901521_TV22077_JUL2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 22 in.
- Width
- 25 in.
- Upstream MH
- H 0751
- Downstream MH
- H 0752
- Dir. of Survey
- Upstream
- Length Surveyed
- 824 ft.
- Total Length
- 824 ft.
- Structural Index
- 2
- Structural Quick
- 3[2`
- Structural Rating
- 748
- O&M Index
- 2
- O&M Quick
- 412`
- O&M Rating
- 332
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 1080
Pipe schematic from manhole H 0751 to H 0752 Observation photos (3)

2 ft. - General Observation - 65% MAG COAT

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

123.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start