Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 19, 2014, 07:06 PM
  • 14 0367A_14 0367_20141219_120423.mp4

Date
12/19/2014
W/O
479094
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00581
PipeID
P18445
Time
11:06 AM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2160
Sewer Name
14 TRUNK "E"
City
LANCASTER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
07
Purpose
Infiltration/Inflow Investigation
Project
WO_479094_2014NOVEMBER_U
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
14 0367
Downstream MH
14 0367A
Dir. of Survey
Upstream
Length Surveyed
208.8 ft.
Total Length
208.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 14 0367 to 14 0367A
MH: 14 0367MH: 14 0367Aupstream0 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - DUE TO DEBRIS IN PIPE0 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish16 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"28.7 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start39.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"65.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"90.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"116.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"139.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"164.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"192.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"206.7 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start208.8 ft. AMH - Downstream Manhole, Survey Begins - 14 0367 (11:06)208.8 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (5)

  • Downstream Manhole, Survey Begins - 14 0367 (11:06)

    0 ft. - Downstream Manhole, Survey Begins - 14 0367 (11:06)

  • Deposits Settled Fine,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    68.9 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

    180.1 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

  • Survey Abandoned - DUE TO DEBRIS IN PIPE

    208.8 ft. - Survey Abandoned - DUE TO DEBRIS IN PIPE

Observations (15)

DistanceCodeObservation
92.5TFC
68.9TFA
44.7TFC
208.8DSF
143.2TFC
2.1DSF
180.1SAV
208.8MSADUE TO DEBRIS IN PIPE
0AMH14 0367 (11:06)
118.7TFC
169.6TFC
16.6TFC
192.8TFC
0MWL
208.8SAV

Properties (7)

custom_field_three
Incomplete due to Debris
custom_field_two
5
customer
LACSD
datetime
2014-12-19T11:06:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false
year_laid
19980518