Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 8, 2014, 01:38 PM
  • 14 0339_14 0338_08122014_055442.mp4

Date
12/08/2014
W/O
476827
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00583
PipeID
P18414
Time
5:38 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K1920
Sewer Name
14 TRUNK "F"
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
10
Purpose
Routine Assessment
Project
WO_476827_TV14027_2014NOVEMBER
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
14 0339
Downstream MH
14 0338
Dir. of Survey
Downstream
Length Surveyed
317.3 ft.
Total Length
317.3 ft.
Structural Index
3
Structural Quick
3K2B
Structural Rating
220
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
220
Pipe schematic from manhole 14 0339 to 14 0338
MH: 14 0339MH: 14 0338downstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 03390 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start28.5 ft. MWL - Water Level, 20 %of cross sectional area47.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 8"113.8 ft. SSS - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: YES116.8 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start125.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"158.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish201.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"275 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"275.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start314.6 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish314.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317.3 ft. AMH - Downstream Manhole, Survey Ends - 14 0338

Observation photos (13)

  • Upstream Manhole, Survey Begins - 14 0339

    0 ft. - Upstream Manhole, Survey Begins - 14 0339

  • Water Mark, 35 %of cross sectional area

    0 ft. - Water Mark, 35 %of cross sectional area

  • Water Level, 15 %of cross sectional area

    0 ft. - Water Level, 15 %of cross sectional area

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Water Level, 20 %of cross sectional area

    28.5 ft. - Water Level, 20 %of cross sectional area

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 8"

    47.4 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 8"

  • Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: YES

    113.8 ft. - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    116.8 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"

    125.3 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    201.1 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    275 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    275.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Downstream Manhole, Survey Ends - 14 0338

    317.3 ft. - Downstream Manhole, Survey Ends - 14 0338

Observations (16)

DistanceCodeObservation
317.3AMH14 0338
2.2SAP
201.1TFA
116.8SSS
28.5MWL
0AMH14 0339
158.3SSS
125.3TFA
314.6SSS
0MWM
275.3SSS
47.4TFA
314.6SAP
275TFC
0MWL
113.8SSS

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2014-12-08T05:38:22-08:00
documentation
PRO PIPE
is_lateral_inspection
false