Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 19, 2014, 05:11 PM
  • F 0240_F 0239_20141202_022557.mp4

Date
11/19/2014
W/O
475177
Weather
Dry
Operator/Surveyor
ERU
Sewer ID
Z00039
PipeID
P10193
Time
9:11 AM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1959
Sewer Name
F JOINT OUTFALL F - UNIT 4
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
WO_475177_TV02238_2014NOVEMBER
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Upstream MH
F 0240
Downstream MH
F 0239
Dir. of Survey
Downstream
Length Surveyed
215.9 ft.
Total Length
215.9 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
78
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
82
Pipe schematic from manhole F 0240 to F 0239
MH: F 0240MH: F 0239downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01308 ft. MGO - General Observation - MAG COATING THROUGHOUT PIPE8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start136 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish215.9 ft. MSA - Survey Abandoned - A/S SLOW FLOW COULD NOT CONTINUE IN PIPE

Observation photos (1)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
215.9MSAA/S SLOW FLOW COULD NOT CONTINUE IN PIPE
0MWM
8MGOMAG COATING THROUGHOUT PIPE
8SAV
136SAV
0MWL
0AMH0130

Properties (5)

custom_field_two
5
customer
LACSD
datetime
2014-11-19T09:11:35-08:00
documentation
PROPIPE
is_lateral_inspection
false