Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 27, 2021, 07:55 AM
  • J 0014_J 0012_07272021_012404.mp4

Date
07/27/2021
W/O
901694
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00060
PipeID
P11597
Time
12:55 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9046
Sewer Name
J JOINT OUTFALL J - UNIT 2A
City
HARBOR CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
33
Purpose
Routine Assessment
Project
RFIR_WO_901694_TV08171_JUL2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
J 0014
Downstream MH
J 0012
Dir. of Survey
Downstream
Length Surveyed
485.2 ft.
Total Length
485.2 ft.
Structural Index
4
Structural Quick
5R3P
Structural Rating
720
O&M Index
2
O&M Quick
412R
O&M Rating
196
Overall Index
3
Overall Quick
Overall Rating
916
Pipe schematic from manhole J 0014 to J 0012
MH: J 0014MH: J 0012downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 00142 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start20.7 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start56.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start129.4 ft. MWL - Water Level, 40 %of cross sectional area139.9 ft. MWM - Water Mark, 50 %of cross sectional area177 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO482.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish482.3 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - NOTE: AS NOTED @ 177.03' THERE CAN BE EXCEPTION(S) TO "BEING WITHIN 8" OF JOINT".482.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish485.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE485.2 ft. AMH - Downstream Manhole, Survey Ends - J 0012485.2 ft. MGO - General Observation - CONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK (BOTH ACTIVE)

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    56.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    485.2 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (15)

DistanceCodeObservation
485.2MGOCOCKROACHES IN MANHOLE
56.6SAP
20.7SRV
482.3DAGS
0MWL
129.4MWL
482.3SRVNOTE: AS NOTED @ 177.03' THERE CAN BE EXCEPTION(S) TO "BEING WITHIN 8" OF JOINT".
139.9MWM
2DAGS
485.2AMHJ 0012
0MWM
482.3SAP
0AMHJ 0014
177SRV
485.2MGOCONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK (BOTH ACTIVE)

Properties (7)

additional_info
630069072621202
custom_field_three
VISIBLE REINFORCEMENT/PROJECTING AGGREGATE
custom_field_two
2
customer
1
datetime
2021-07-27T00:55:08-07:00
documentation
PRO PIPE
is_lateral_inspection
false