- Date
- 07/27/2021
- W/O
- 901694
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00060
- PipeID
- P11588
- Time
- 3:16 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9046
- Sewer Name
- J JOINT OUTFALL J - UNIT 2A
- City
- TORRANCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- RFIR_WO_901694_TV08171_JUL2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Width
- 57 in.
- Upstream MH
- J 0001
- Downstream MH
- D 0150
- Dir. of Survey
- Downstream
- Length Surveyed
- 220.9 ft.
- Total Length
- 220.9 ft.
- Structural Index
- 3
- Structural Quick
- 5C3H
- Structural Rating
- 320
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 320
Pipe schematic from manhole J 0001 to D 0150 Observation photos (3)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

112.1 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start