Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 11, 2021, 08:19 AM
  • 02 1765_02 1764_8112021_033831.mp4

Date
08/11/2021
W/O
0890811
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00271
PipeID
P04112
Time
1:19 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1909
Sewer Name
02 INDIANA STREET TRUNK
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
11A
Purpose
Routine Assessment
Project
20210810MDM_INDINA_STREET_TRUNK
Material
NRCP
Shape
Circular
Height
7.53000020980835 in.
Upstream MH
02 1765
Downstream MH
02 1764
Dir. of Survey
Downstream
Length Surveyed
171.8 ft.
Total Length
171.8 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 1765 to 02 1764
MH: 02 1765MH: 02 1764downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:35AM0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - FIBOROUS BLISTERING OUTER SURFACE8 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBOROUS OUTER SURFACE125.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open156.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open159 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open171.3 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish - FIBOROUS OUTER SURFACE171.3 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - ROCKS171.8 ft. MSA - Survey Abandoned - 10% ROCKS

Observation photos (2)

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - FIBOROUS BLISTERING OUTER SURFACE

    2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - FIBOROUS BLISTERING OUTER SURFACE

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBOROUS OUTER SURFACE

    8 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBOROUS OUTER SURFACE

Observations (11)

DistanceCodeObservation
159TBOpen
125.2TBOpen
0AMH3:35AM
0MWL
156.9TBOpen
171.3SSSFIBOROUS OUTER SURFACE
171.8MSA10% ROCKS
171.3DSZROCKS
0MWM
8SSSFIBOROUS OUTER SURFACE
2SSSFIBOROUS BLISTERING OUTER SURFACE

Properties (5)

customer
LACSD
datetime
2021-08-11T01:19:33-07:00
documentation
MARTIN,OLIVER 111,BARR,RAMERIZ
is_lateral_inspection
false
lining
CIPP