Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2021, 07:33 AM
  • 02 1770_02 1769_8102021_003903.mp4

Date
08/10/2021
W/O
0890811
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00271
PipeID
P04117
Time
12:33 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1907
Sewer Name
02 INDIANA STREET TRUNK
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
11A
Purpose
Routine Assessment
Project
20210810MDM_INDINA_STREET_TRUNK
Material
NRCP
Shape
Circular
Height
7.53000020980835 in.
Upstream MH
02 1770
Downstream MH
02 1769
Dir. of Survey
Downstream
Length Surveyed
354.8 ft.
Total Length
354.8 ft.
Structural Index
2
Structural Quick
2400
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 1770 to 02 1769
MH: 02 1770MH: 02 1769downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:35AM2 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO, Start - FIBOROUS BLISTERING OUTER SURFACE9 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBOROUS PIPE AREAS BESIDE NON FIBOROUS AREA32.2 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBERS BLISTERING OUT OF CIPP LINER48.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FIBOROUS LINES RUNNING DOWN PIPE257.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open294.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open354.3 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO, Finish - FIBOROUS BLISTERING OUTER SURFACE354.8 ft. AMH - Downstream Manhole, Survey Ends - 1:30AM

Observation photos (4)

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO, Start - FIBOROUS BLISTERING OUTER SURFACE

    2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO, Start - FIBOROUS BLISTERING OUTER SURFACE

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBOROUS PIPE AREAS BESIDE NON FIBOROUS AREA

    9 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBOROUS PIPE AREAS BESIDE NON FIBOROUS AREA

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBERS BLISTERING OUT OF CIPP LINER

    32.2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - FIBERS BLISTERING OUT OF CIPP LINER

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FIBOROUS LINES RUNNING DOWN PIPE

    48.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FIBOROUS LINES RUNNING DOWN PIPE

Observations (11)

DistanceCodeObservation
354.3SSSFIBOROUS BLISTERING OUTER SURFACE
32.2SSSFIBERS BLISTERING OUT OF CIPP LINER
9SSSFIBOROUS PIPE AREAS BESIDE NON FIBOROUS AREA
0MWM
294.8TBOpen
0MWL
257.3TBOpen
48.1SSSFIBOROUS LINES RUNNING DOWN PIPE
2SSSFIBOROUS BLISTERING OUTER SURFACE
354.8AMH1:30AM
0AMH12:35AM

Properties (6)

customer
LACSD
datetime
2021-08-10T00:33:51-07:00
documentation
MARTIN,REVELES,OLIVER 111,RAMERIZ
is_lateral_inspection
false
lining
CIPP
year_laid
20060517