- Date
- 12/02/2014
- W/O
- 474772
- Weather
- Light Rain
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00947
- PipeID
- P20658
- Time
- 11:57 PM
- Certificate
- U507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K1687
- Sewer Name
- 14 AVENUE "I" WEST TRUNK
- City
- LANCASTER, CA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 02A
- Purpose
- Routine Assessment
- Project
- WO_474772_TV14046_2014NOVEMBER
- Sewer Type
- GRAVITY
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- 14 0775
- Downstream MH
- 14 0776
- Dir. of Survey
- Upstream
- Length Surveyed
- 573.7 ft.
- Total Length
- 573.7 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2111
- O&M Rating
- 3
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole 14 0775 to 14 0776 Observation photos (4)

0 ft. - Downstream Manhole, Survey Begins - 14 0775 (22:57)

3.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

156.6 ft. - Vermin Cockroach, within 8 inches of joint: YES

572.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish