Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 14, 2021, 08:59 AM
  • B 1168_B 1167_07142021_020828.mp4

Date
07/14/2021
W/O
901874
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01125
PipeID
P13488
Time
1:59 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8677
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_901874_TV16072_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
B 1168
Downstream MH
B 1167
Dir. of Survey
Downstream
Length Surveyed
250.5 ft.
Total Length
250.5 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole B 1168 to B 1167
MH: B 1168MH: B 1167downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 11680 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area1.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start29.9 ft. CS - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES188.5 ft. CS - Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES248.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish250.5 ft. AMH - Downstream Manhole, Survey Ends - B 1167

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    1.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

    29.9 ft. - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

    188.5 ft. - Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
29.9CS
250.5AMHB 1167
0AMHB 1168
1.8DAGS
188.5CS
0MWL
0MWM
248.4DAGS

Properties (7)

additional_info
630138071321201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-07-14T01:59:15-07:00
documentation
PROPIPE
is_lateral_inspection
false