- Date
- 07/14/2021
- W/O
- 901874
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z01125
- PipeID
- P13486
- Time
- 12:48 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8677
- Sewer Name
- B JOINT OUTFALL B - UNIT 6H
- City
- SOUTH PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- RFIR_WO_901874_TV16072_JUL2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- B 1166
- Downstream MH
- B 1165
- Dir. of Survey
- Downstream
- Length Surveyed
- 265.6 ft.
- Total Length
- 265.6 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole B 1166 to B 1165 Observation photos (3)

2.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

153.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

194 ft. - Crack Spiral, from 03 to 09 o'clock, within 8 inches of joint: YES