Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 20, 2021, 08:12 AM
  • B 1163_B 1162_07202021_014105.mp4

Date
07/20/2021
W/O
901874
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01125
PipeID
P13483
Time
1:12 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8680
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
SOUTH PASADENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_901874_TV16072_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
B 1163
Downstream MH
B 1162
Dir. of Survey
Downstream
Length Surveyed
485.1 ft.
Total Length
485.1 ft.
Structural Index
3
Structural Quick
3423
Structural Rating
18
O&M Index
1
O&M Quick
2113
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
23
Pipe schematic from manhole B 1163 to B 1162
MH: B 1163MH: B 1162downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 11632.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start24.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"34.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"45.3 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"69 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"86.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"97.6 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 4"104.1 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES120.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"134.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"148.1 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES150.7 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES153.2 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES160.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"161.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES161.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 4"175.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"186.4 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6"202.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"230.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"277.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"321.8 ft. RFL - Roots Fine Lateral, from 02 to 03 o'clock321.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"324.7 ft. RFL - Roots Fine Lateral, from 08 to 10 o'clock324.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"344.6 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES375.4 ft. CS - Crack Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES442.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"448.5 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES466.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"480.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"483.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish485.1 ft. AMH - Downstream Manhole, Survey Ends - B 1162

Observation photos (11)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    104.1 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

    148.1 ft. - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    150.7 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    153.2 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    161.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Roots Fine Lateral, from 02 to 03 o'clock

    321.8 ft. - Roots Fine Lateral, from 02 to 03 o'clock

  • Roots Fine Lateral, from 08 to 10 o'clock

    324.7 ft. - Roots Fine Lateral, from 08 to 10 o'clock

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    344.6 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES

    375.4 ft. - Crack Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES

    448.5 ft. - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES

Observations (36)

DistanceCodeObservation
150.7CM
45.3TB
324.7RFL
2.3DAGS
175.9TFC
466.5TF
160.1TF
104.1CL
186.4TB
277.7TFA
321.8RFL
202.1TF
0MWM
375.4CS
161.7TB
120.9TFC
448.5RFJ
34.4TFC
485.1AMHB 1162
483.7DAGS
97.6TB
442.9TB
324.7TF
230.9TFC
153.2CM
321.8TF
480.1TF
134.3TF
0MWL
86.8TFC
24.7TF
148.1CM
69TFC
344.6CM
0AMHB 1163
161.4CL

Properties (7)

additional_info
630138071921202
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-07-20T01:12:49-07:00
documentation
PROPIPE
is_lateral_inspection
false