Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2021, 08:04 AM
  • B 1133_B 1132_07132021_012404.mp4

Date
07/13/2021
W/O
901874
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01125
PipeID
P13173
Time
1:04 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8676
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
ALHAMBRA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_901874_TV16072_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
B 1133
Downstream MH
B 1132
Dir. of Survey
Downstream
Length Surveyed
293 ft.
Total Length
293 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole B 1133 to B 1132
MH: B 1133MH: B 1132downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - B 11330 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area4 ft. MGO - General Observation - LIGHT STEAM IN SEWER4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: NO10 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO20.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"34 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start43.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"44.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"47.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4"62.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"66.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"89.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"93 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 4"104.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"124.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"127.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"150.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"153.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"183.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"191.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"202.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"221.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"224.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"240.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"250.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"251.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"270.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"291.9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish293 ft. AMH - Downstream Manhole, Survey Ends - B 1132

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 09 o'clock,  , within 8 inches of joint: NO

    4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: NO

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO

    10 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    34 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (33)

DistanceCodeObservation
44.6TB
191.1TF
66.3TFC
93TB
89.6TFC
250.5TB
240.3TFC
293AMHB 1132
173.1TF
43.9TF
127.5TFC
224.4TFC
4MGOLIGHT STEAM IN SEWER
221.5TFC
291.9CM
0MGOCONNECTION AT MH 9 O'CLOCK
183.9TF
150.5TF
4DAGS
251.2TFC
104.8TF
62.8TFC
124.1TFA
34CM
270.3TFC
202.4TFC
0AMHB 1133
10CL
153.9TF
20.5TFC
47.5TB
0MWM
0MWL

Properties (7)

additional_info
630138071221201
custom_field_three
CRACK MULTIPLE
custom_field_two
3
customer
1
datetime
2021-07-13T01:04:18-07:00
documentation
PROPIPE
is_lateral_inspection
false