Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 18, 2014, 09:59 AM
  • 32 0216_32 0184_20141118_020853.mp4

Date
11/18/2014
W/O
470382
Weather
Dry
Operator/Surveyor
C.DEHNER
Sewer ID
Z00891
PipeID
P19939
Time
1:59 AM
Certificate
U-912-15963
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1641
Sewer Name
32 VALENCIA TRUNK
City
VALENCIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
07
Purpose
Routine Assessment
Project
WO_470382_TV32028_2014OCTOBER
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
32 0216
Downstream MH
32 0184
Dir. of Survey
Downstream
Length Surveyed
46.7 ft.
Total Length
46.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
4129
O&M Rating
22
Overall Index
2
Overall Quick
Overall Rating
22
Pipe schematic from manhole 32 0216 to 32 0184
MH: 32 0216MH: 32 0184downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 02160 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 65 %of cross sectional area6.9 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start23.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - UNKNOWN44.6 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish46.7 ft. AMH - Downstream Manhole, Survey Ends - 32 018446.7 ft. MGO - General Observation - CONNECTION AT MANHOLE

Observation photos (2)

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    6.9 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Settled Other,  10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - UNKNOWN

    23.2 ft. - Deposits Settled Other, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - UNKNOWN

Observations (8)

DistanceCodeObservation
46.7AMH32 0184
0AMH32 0216
0MWL
0MWM
6.9DAGS
23.2DSZUNKNOWN
46.7MGOCONNECTION AT MANHOLE
44.6DAGS

Properties (6)

custom_field_two
4
customer
LACSD
datetime
2014-11-18T01:59:48-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
19830201