- Date
- 11/19/2014
- W/O
- 470293
- Weather
- Dry
- Operator/Surveyor
- C. DEHNER
- Sewer ID
- Z00885
- PipeID
- P19965
- Time
- 11:16 PM
- Certificate
- U-912-15963
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K1643
- Sewer Name
- 32 AVENUE SCOTT TRUNK
- City
- VALENCIA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 32
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- WO_0470293_TV32003_2014OCTOBER
- Sewer Type
- GRAVITY
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 32 0210
- Downstream MH
- 32 0209
- Dir. of Survey
- Downstream
- Length Surveyed
- 335.2 ft.
- Total Length
- 335.2 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 132
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 137
Pipe schematic from manhole 32 0210 to 32 0209 Observation photos (3)

2.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

180.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

203.9 ft. - Surface Spalling, at 09 o'clock, within 8 inches of joint: YES