Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 21, 2014, 08:16 AM
  • 32 0201_32 0200_20141121_003155.mp4

Date
11/21/2014
W/O
470293
Weather
Dry
Operator/Surveyor
C. DEHNER
Sewer ID
Z00885
PipeID
P19956
Time
12:16 AM
Certificate
U-912-15963
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1646
Sewer Name
32 AVENUE SCOTT TRUNK
City
VALENCIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
04
Purpose
Routine Assessment
Project
WO_0470293_TV32003_2014OCTOBER
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
32 0201
Downstream MH
32 0200
Dir. of Survey
Downstream
Length Surveyed
350.8 ft.
Total Length
350.8 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
2
Overall Quick
Overall Rating
140
Pipe schematic from manhole 32 0201 to 32 0200
MH: 32 0201MH: 32 0200downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 02012 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start4.2 ft. CS - Crack Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES159.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN348 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish350.8 ft. AMH - Downstream Manhole, Survey Ends - 32 0200

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

    4.2 ft. - Crack Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

    159.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

Observations (8)

DistanceCodeObservation
4.2CS
159.7TBOPEN
348DAGS
0MWM
2DAGS
350.8AMH32 0200
0MWL
0AMH32 0201

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2014-11-21T00:16:06-08:00
documentation
PROPIPE
is_lateral_inspection
false