Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 14, 2014, 11:11 AM
Date
11/14/2014
W/O
470269
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00622
PipeID
P11911
Time
3:11 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1855
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_0470269_TV15026_2014OCTOBER_1
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
15 0022
Downstream MH
15 0021
Dir. of Survey
Downstream
Length Surveyed
464 ft.
Total Length
464 ft.
Structural Index
2
Structural Quick
332E
Structural Rating
69
O&M Index
2
O&M Quick
2A00
O&M Rating
20
Overall Index
2
Overall Quick
Overall Rating
89
Pipe schematic from manhole 15 0022 to 15 0021
MH: 15 0022MH: 15 0021downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area7.4 ft. DSGV - Deposits Settled Gravel, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start12.4 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"32.8 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"63.1 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"98.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN129 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"139.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.6 ft. DSGV - Deposits Settled Gravel, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish179.4 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"198.8 ft. CM - Crack Multiple, from 01 to 02 o'clock, within 8 inches of joint: YES200 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"230.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"245.3 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"248.4 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"275.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES279.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES281 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"288.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start305 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6" - Unkown331.7 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"352.2 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"367.1 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"379.5 ft. CM - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES390.7 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES402.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"428.1 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"429.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish462.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish464 ft. AMH - Downstream Manhole, Survey Ends - 15 0021464 ft. MGO - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, ACTIVE464 ft. MGO - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

Observations (34)

DistanceCodeObservation
428.1TBA
379.5CM
331.7TBC
464AMH15 0021
0MWL
245.3TBC
139.4TB
279.1CL
12.4TBC
352.2TBC
402.8TFC
129TBA
248.4TBA
32.8TBA
179.4TBA
0MWM
462.7DAGS
367.1TBA
63.1TBC
275.2CL
390.7CM
288.3CL
200TBC
429.6CL
98.5TBOPEN
198.8CM
281TBA
8DAGS
142.6DSGV
464MGOCONNECTION AT MANHOLE 3 O'CLOCK, ACTIVE
7.4DSGV
230.1TBA
305TFUnkown
464MGOCONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2014-11-14T03:11:32-08:00
documentation
PROPIPE
is_lateral_inspection
false