Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 14, 2014, 10:41 AM
  • 15 0023_15 0022_20141114_025756.mp4

Date
11/14/2014
W/O
470269
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00622
PipeID
P11912
Time
2:41 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1855
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_0470269_TV15026_2014OCTOBER_1
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
15 0023
Downstream MH
15 0022
Dir. of Survey
Downstream
Length Surveyed
452.3 ft.
Total Length
452.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2K00
O&M Rating
124
Overall Index
2
Overall Quick
Overall Rating
124
Pipe schematic from manhole 15 0023 to 15 0022
MH: 15 0023MH: 15 0022downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 00230 ft. MWM - Water Mark, 20 %of cross sectional area23.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE49.1 ft. TBC - Tap Break-In Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"89.2 ft. TBC - Tap Break-In Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"99.5 ft. TBC - Tap Break-In Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"124.7 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"149.6 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.6 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"174.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start195.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"215.4 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"235.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"250.9 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"261.9 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"291.5 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"326.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN346.9 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"364.5 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"382 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN402 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"427.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN442.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"450.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish452.3 ft. AMH - Downstream Manhole, Survey Ends - 15 0022

Observation photos (26)

  • Water Level, 10 %of cross sectional area

    0 ft. - Water Level, 10 %of cross sectional area

  • Upstream Manhole, Survey Begins - 15 0023

    0 ft. - Upstream Manhole, Survey Begins - 15 0023

  • Water Mark, 20 %of cross sectional area

    0 ft. - Water Mark, 20 %of cross sectional area

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

    23.5 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

  • Tap Break-In Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"

    49.1 ft. - Tap Break-In Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"

    89.2 ft. - Tap Break-In Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"

    99.5 ft. - Tap Break-In Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"

    124.7 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    149.6 ft. - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    174.6 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    174.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    195.3 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    215.4 ft. - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    235.9 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    250.9 ft. - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"

    261.9 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    291.5 ft. - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    326.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    346.9 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    364.5 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    382 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    402 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    427.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    442.7 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Finish

    450.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish

  • Downstream Manhole, Survey Ends - 15 0022

    452.3 ft. - Downstream Manhole, Survey Ends - 15 0022

Observations (26)

DistanceCodeObservation
452.3AMH15 0022
235.9TBA
0MWL
261.9TBA
364.5TBA
442.7TFC
99.5TBC
124.7TBA
89.2TBC
149.6TBC
174.6TBA
346.9TBA
0AMH15 0023
291.5TBC
326.9TBOPEN
195.3TFC
402TBA
450.9DAGS
0MWM
215.4TBC
174.6DAGS
23.5TBACTIVE
250.9TBC
427.5TBOPEN
382TBOPEN
49.1TBC

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2014-11-14T02:41:09-08:00
documentation
PROPIPE
is_lateral_inspection
false