Wastewater/Activity/PacpInspection/1.0Nov 17, 2014, 09:29 AM
  • 15 0017_15 0016_20141117_015051.mp4

Date
11/17/2014
W/O
470269
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00622
PipeID
P11906
Time
1:29 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1861
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
30
Purpose
Routine Assessment
Project
WO_0470269_TV15026_2014OCTOBER_1
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
15 0017
Downstream MH
15 0016
Dir. of Survey
Downstream
Length Surveyed
499.5 ft.
Total Length
499.5 ft.
Structural Index
2
Structural Quick
312A
Structural Rating
27
O&M Index
2
O&M Quick
2W00
O&M Rating
240
Overall Index
2
Overall Quick
Overall Rating
267
Pipe schematic from manhole 15 0017 to 15 0016
MH: 15 0017MH: 15 0016downstream0 ft. MGO - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, OPEN0 ft. MGO - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start0 ft. AMH - Upstream Manhole, Survey Begins - 15 001727.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN34.1 ft. DSF - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start81.4 ft. DSF - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish88.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"120.5 ft. DSF - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start126.3 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES127.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"130.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN153.4 ft. DSF - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish173.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"224 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"263.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO264.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"289.3 ft. RFB - Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO - COMING OUT OF TAP289.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"344 ft. CM - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES365.2 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"368.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start386.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"426.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish435.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES436.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"487.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"499.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish499.5 ft. AMH - Downstream Manhole, Survey Ends - 15 0016499.5 ft. MGO - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, ACTIVE499.5 ft. MGO - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

Observation photos (33)

  • General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, OPEN

    0 ft. - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, OPEN

  • General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

    0 ft. - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

  • Water Mark, 20 %of cross sectional area

    0 ft. - Water Mark, 20 %of cross sectional area

  • Water Level, 10 %of cross sectional area

    0 ft. - Water Level, 10 %of cross sectional area

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Upstream Manhole, Survey Begins - 15 0017

    0 ft. - Upstream Manhole, Survey Begins - 15 0017

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    27.8 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Deposits Settled Fine,  5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    34.1 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Settled Fine,  5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Finish

    81.4 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    88.1 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Deposits Settled Fine,  5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    120.5 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    126.3 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    127.7 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN

    130.1 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN

  • Deposits Settled Fine,  5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Finish

    153.4 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    173.3 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    224 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: NO

    263.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    264.9 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO - COMING OUT OF TAP

    289.3 ft. - Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO - COMING OUT OF TAP

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    289.3 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

    344 ft. - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    365.2 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    368.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    386.2 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish

    426.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    435.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    436.6 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    487.6 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Finish

    499.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

  • Downstream Manhole, Survey Ends - 15 0016

    499.5 ft. - Downstream Manhole, Survey Ends - 15 0016

  • General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, ACTIVE

    499.5 ft. - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, ACTIVE

  • General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

    499.5 ft. - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

Observations (33)

DistanceCodeObservation
289.3RFBCOMING OUT OF TAP
224TFC
264.9TBA
27.8TFOPEN
344CM
120.5DSF
81.4DSF
426.6CL
487.6TFC
499.2DAGS
499.5AMH15 0016
0MGOCONNECTION AT MANHOLE 3 O'CLOCK, OPEN
386.2TFA
0MGOCONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE
153.4DSF
173.3TFA
499.5MGOCONNECTION AT MANHOLE 3 O'CLOCK, ACTIVE
499.5MGOCONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE
126.3DAE
0MWM
365.2TBA
0MWL
34.1DSF
0DAGS
436.6TFA
263.4DAGS
368.2CL
88.1TFA
435.1DAGS
0AMH15 0017
127.7TFA
289.3TFA
130.1TBUNKNOWN