15 0017_15 0016_20141117_015051.mp4
0 ft. - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, OPEN
0 ft. - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE
0 ft. - Water Mark, 20 %of cross sectional area
0 ft. - Water Level, 10 %of cross sectional area
0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
0 ft. - Upstream Manhole, Survey Begins - 15 0017
27.8 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN
34.1 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
81.4 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish
88.1 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
120.5 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
126.3 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES
127.7 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
130.1 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN
153.4 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish
173.3 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
224 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"
263.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO
264.9 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
289.3 ft. - Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO - COMING OUT OF TAP
289.3 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
344 ft. - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES
365.2 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
368.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start
386.2 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
426.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish
435.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES
436.6 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"
487.6 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"
499.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish
499.5 ft. - Downstream Manhole, Survey Ends - 15 0016
499.5 ft. - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, ACTIVE
499.5 ft. - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE
| Distance | Code | Observation |
|---|---|---|
| 289.3 | RFB | COMING OUT OF TAP |
| 224 | TFC | — |
| 264.9 | TBA | — |
| 27.8 | TF | OPEN |
| 344 | CM | — |
| 120.5 | DSF | — |
| 81.4 | DSF | — |
| 426.6 | CL | — |
| 487.6 | TFC | — |
| 499.2 | DAGS | — |
| 499.5 | AMH | 15 0016 |
| 0 | MGO | CONNECTION AT MANHOLE 3 O'CLOCK, OPEN |
| 386.2 | TFA | — |
| 0 | MGO | CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE |
| 153.4 | DSF | — |
| 173.3 | TFA | — |
| 499.5 | MGO | CONNECTION AT MANHOLE 3 O'CLOCK, ACTIVE |
| 499.5 | MGO | CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE |
| 126.3 | DAE | — |
| 0 | MWM | — |
| 365.2 | TBA | — |
| 0 | MWL | — |
| 34.1 | DSF | — |
| 0 | DAGS | — |
| 436.6 | TFA | — |
| 263.4 | DAGS | — |
| 368.2 | CL | — |
| 88.1 | TFA | — |
| 435.1 | DAGS | — |
| 0 | AMH | 15 0017 |
| 127.7 | TFA | — |
| 289.3 | TFA | — |
| 130.1 | TB | UNKNOWN |