Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 18, 2014, 07:23 AM
  • 15 0007_15 0006_20141117_233842.mp4

Date
11/17/2014
W/O
470269
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00622
PipeID
P11895
Time
11:23 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1862
Sewer Name
15 PUENTE TRUNK
City
LA PUENTE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
29
Purpose
Routine Assessment
Project
WO_0470269_TV15026_2014OCTOBER_1
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
15 0007
Downstream MH
15 0006
Dir. of Survey
Downstream
Length Surveyed
351.6 ft.
Total Length
351.6 ft.
Structural Index
3
Structural Quick
3321
Structural Rating
11
O&M Index
2
O&M Quick
2F00
O&M Rating
66
Overall Index
2
Overall Quick
Overall Rating
77
Pipe schematic from manhole 15 0007 to 15 0006
MH: 15 0007MH: 15 0006downstream0 ft. MGO - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 00070 ft. MWL - Water Level, 15 %of cross sectional area13.4 ft. CM - Crack Multiple, from 10 to 05 o'clock, within 8 inches of joint: YES20.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"48 ft. MWLS - Water Level, Sag in pipe, 5 %of cross sectional area48 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"70.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"98.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"115.2 ft. CM - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES122 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"145.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"168.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN183 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start196.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"212.6 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES244.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"272.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"295.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"323.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"348.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish351.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0006

Observation photos (23)

  • General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

    0 ft. - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

  • Water Mark, 20 %of cross sectional area

    0 ft. - Water Mark, 20 %of cross sectional area

  • Upstream Manhole, Survey Begins - 15 0007

    0 ft. - Upstream Manhole, Survey Begins - 15 0007

  • Water Level, 15 %of cross sectional area

    0 ft. - Water Level, 15 %of cross sectional area

  • Crack Multiple, from 10 to 05 o'clock, within 8 inches of joint: YES

    13.4 ft. - Crack Multiple, from 10 to 05 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    20.1 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Water Level, Sag in pipe, 5 %of cross sectional area

    48 ft. - Water Level, Sag in pipe, 5 %of cross sectional area

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    48 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    70.7 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    98.8 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

    115.2 ft. - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    122 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    145.2 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    168.3 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    183 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    196.3 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    212.6 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    244.5 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    272.4 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    295.4 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    323.6 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Finish

    348.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish

  • Downstream Manhole, Survey Ends - 15 0006

    351.6 ft. - Downstream Manhole, Survey Ends - 15 0006

Observations (23)

DistanceCodeObservation
348.9DAGS
0MGOCONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE
0MWM
351.6AMH15 0006
115.2CM
13.4CM
323.6TFC
0AMH15 0007
212.6CM
145.2TFC
20.1TFC
98.8TFC
48MWLS
70.7TFC
295.4TFC
183DAGS
122TFC
0MWL
48TFC
168.3TFOPEN
244.5TFC
272.4TFC
196.3TFC

Properties (6)

custom_field_three
CRACKS
custom_field_two
4
customer
LACSD
datetime
2014-11-17T23:23:43-08:00
documentation
PROPIPE
is_lateral_inspection
false