Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 18, 2014, 06:42 AM
Date
11/17/2014
W/O
470269
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00622
PipeID
P11897
Time
10:42 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1862
Sewer Name
15 PUENTE TRUNK
City
LA PUENTE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
29
Purpose
Routine Assessment
Project
WO_0470269_TV15026_2014OCTOBER_1
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
15 0009
Downstream MH
15 0008
Dir. of Survey
Downstream
Length Surveyed
465.9 ft.
Total Length
465.9 ft.
Structural Index
3
Structural Quick
3700
Structural Rating
21
O&M Index
2
O&M Quick
2Q00
O&M Rating
184
Overall Index
2
Overall Quick
Overall Rating
205
Pipe schematic from manhole 15 0009 to 15 0008
MH: 15 0009MH: 15 0008downstream0 ft. MGO - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area5.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start67.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"68.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES100.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"129 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"147.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"198.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"211.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN249.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"251.1 ft. CM - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES272.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN295.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"297.5 ft. CM - Crack Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES323.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"330.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES346.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"363.1 ft. CM - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES368.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"370.7 ft. CM - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES396.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"424.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"447.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"459.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES462.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish465.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0008

Observations (29)

DistanceCodeObservation
100.6TFC
346.3TFC
251.1CM
323.9TFC
0MGOCONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE
198.4TFC
249.4TFC
363.1CM
67.3TFC
211.4TFOPEN
297.5CM
147.2TFC
5.2DAGS
462.8DAGS
295.7TFC
424.8TFC
175.1TFC
447.4TFC
68.6CM
272.5TFOPEN
465.9AMH15 0008
396.4TFC
370.7CM
129TFA
330.3CM
0MWL
368.6TFC
0MWM
459.1CM

Properties (6)

custom_field_three
CRACKS
custom_field_two
3
customer
LACSD
datetime
2014-11-17T22:42:50-08:00
documentation
PROPIPE
is_lateral_inspection
false