Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2014, 07:01 AM
  • 15 0048_15 0047A_20141112_230839.mp4

Date
11/12/2014
W/O
470269
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00622
PipeID
P11940
Time
11:01 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1854
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Routine Assessment
Project
WO_0470269_TV15026_2014OCTOBER_1
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
15 0048
Downstream MH
15 0047A
Dir. of Survey
Downstream
Length Surveyed
76.8 ft.
Total Length
76.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0048 to 15 0047A
MH: 15 0048MH: 15 0047Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 00480 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area7.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"29.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"56.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"76.7 ft. MGO - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE76.7 ft. MGO - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, UNKNOWN/DEBRIS76.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0047A

Observation photos (9)

  • Upstream Manhole, Survey Begins - 15 0048

    0 ft. - Upstream Manhole, Survey Begins - 15 0048

  • Water Mark, 20 %of cross sectional area

    0 ft. - Water Mark, 20 %of cross sectional area

  • Water Level, 10 %of cross sectional area

    0 ft. - Water Level, 10 %of cross sectional area

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    7.1 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    29.9 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    56.4 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

    76.7 ft. - General Observation - CONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE

  • General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, UNKNOWN/DEBRIS

    76.7 ft. - General Observation - CONNECTION AT MANHOLE 3 O'CLOCK, UNKNOWN/DEBRIS

  • Downstream Manhole, Survey Ends - 15 0047A

    76.8 ft. - Downstream Manhole, Survey Ends - 15 0047A

Observations (9)

DistanceCodeObservation
0AMH15 0048
7.1TFC
76.8AMH15 0047A
29.9TFC
56.4TFC
76.7MGOCONNECTION AT MANHOLE 9 O'CLOCK, ACTIVE
76.7MGOCONNECTION AT MANHOLE 3 O'CLOCK, UNKNOWN/DEBRIS
0MWM
0MWL

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2014-11-12T23:01:50-08:00
documentation
PRO-PIPE
is_lateral_inspection
false