Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2014, 06:22 AM
  • 01 0724A_01 0724_20141112_225852.mp4

Date
11/12/2014
W/O
0470264
Weather
Dry
Operator/Surveyor
ERU
Sewer ID
Z00196
PipeID
P02219
Time
10:22 PM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K1847
Sewer Name
01 BULLIS ROAD RELIEF TRUNK, SECTION 2
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
14
Purpose
Routine Assessment
Project
WO_0470264_TV01201_2014OCTOBER
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Lining Method
Segmented Panel
Shape
Circular
Height
15 in.
Upstream MH
01 0724
Downstream MH
01 0724A
Dir. of Survey
Upstream
Length Surveyed
425.4 ft.
Total Length
425.4 ft.
Structural Index
2
Structural Quick
2811
Structural Rating
17
O&M Index
2
O&M Quick
412P
O&M Rating
172
Overall Index
2
Overall Quick
Overall Rating
189
Pipe schematic from manhole 01 0724 to 01 0724A
MH: 01 0724MH: 01 0724Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 22581.8 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish136.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish178.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start407.7 ft. CC - Crack Circumferential, from 04 to 04 o'clock, within 8 inches of joint: YES419.4 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start425.4 ft. MWM - Water Mark, 50 %of cross sectional area425.4 ft. AMH - Downstream Manhole, Survey Begins - 2240425.4 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: YES, 10"425.4 ft. MWL - Water Level, 45 %of cross sectional area

Observation photos (3)

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    6 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Circumferential, from 04 to 04 o'clock, within 8 inches of joint: YES

    17.7 ft. - Crack Circumferential, from 04 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    246.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
17.7CC
423.6DAGS
288.9CL
6DAGS
0MWM
425.4AMH2258
0AMH2240
0TFA
0MWL
246.6CL

Properties (6)

custom_field_three
CRACKS
custom_field_two
3
customer
LACSD
datetime
2014-11-12T22:22:48-08:00
documentation
PROPIPE
is_lateral_inspection
false