Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 12, 2014, 11:56 AM
  • 02 0821_02 0817_20141212_040130.mp4

Date
12/12/2014
W/O
464882
Weather
Heavy Rain
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00295
PipeID
P03387
Time
3:56 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K1749
Sewer Name
02 OLD RIVER SCHOOL ROAD TRUNK, SECTION 3
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
24
Purpose
Routine Assessment
Project
TV02226
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0821
Downstream MH
02 0817
Dir. of Survey
Downstream
Length Surveyed
13.1 ft.
Total Length
13.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2211
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 0821 to 02 0817
MH: 02 0821MH: 02 0817downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 08210 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area1.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start10.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish12.8 ft. MGO - General Observation - CONNECTION AT THE MH 9 O' CLOCK, active13.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0817

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    1.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH02 0821
1.9DAGS
0VC
0MWL
10.1DAGS
0MWM
12.8MGOCONNECTION AT THE MH 9 O' CLOCK, active
13.1AMH02 0817

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2014-12-12T03:56:50-08:00
documentation
PRO PIPE
is_lateral_inspection
false